The heart of T2000 pressure transmitter is a ceramic pressure sensor (If you need higher accuracy and pressure, we have a transmitter with an oil-washed silicon core) that is temperature compensated and laser trimmed for accurate span and offset calibration. The typical advantage is the compact size, which make it convenient to be installed in small room. Some typical applications for these pressure sensor are: Process control and automation, compressors and pumps, engine controls, off road vehicles to name few.
Specification
General | Value | |||
Measurement Range | -1~0......100bar, 0~2......3bar, 0~4......60bar(normal range), 0~61......600bar | |||
Overload Pressure | 1.5 times of full scales | |||
Burst Pressure | 3 times of full scales | |||
Accuracy | ±0.5%F.S,±1.0%F.S | |||
Long Term Stability | Typical value: 0.5%F.S Maximum: 1%F.S | |||
Working Temperature | -40°C~100°C | |||
Compensated Temperature | -10°C~80°C | |||
Storage Temperature | -50°C~125°C | |||
Medium Compatibility | All corrosive medium compatible with 1Cr18Ni9Ti stainless steel and ceramic | |||
Output Mode | Two-wired | Three-wired | ||
Output | 4~20mA | 0.5~4.5V | 0/1~5V | 0~10V |
Power Supply | 10~30VDC | 5VDC | 10~30VDC/AC | 12~30VDC/AC |
Load Resistance | (U-10)/0.02(Ω) | >100K(Ω) | ||
Insulation | >100M(Ω)@50V | |||
Electrical Connection | Packard, DIN43650C, DIN72585, M12, Cable | |||
Protection Grade | IP67 | |||
Pressure Connection | Male G1/4,NPT1/4,7/16-20UNF,M20×1.5,G1/ (Female and other connection is available on request) | |||
Response Time | 10ms | |||
Pressure Form | Gauge pressure | |||
Electromagnetic Compatibility | Electromagnetic transmit: EN50081-1/-2; Electromagnetic sensitivity: EN50082-2 |
transductor de presión
Ps: 1 box(10-100 pieces) minimum order.Quantity discounts.